Surge Generator T-1016(5)

 

  PREVIOUS NEXT
Suitable for fault location in L.T. to 11 K.V.
High voltage testing up to 16 KVDC.
Limited Burning Capability.
500J Energy on 4, 8, 16 KV Range.
Built in ICM & Decay Coupler for Reflectometer T-510.
Rugged steel body.
Suitable as thumper required for pinpointing of fault.
Suitable to operate on mains (220-230/240 VAC, 45Hz up to 60 Hz) or portable generator.

DESCRIPTION

  • Instrument has been primarily designed to produce high voltage surges for pre-location of under ground cable fault in combination with Reflectometer T-510.

  • The surges produced help in pinpointing the fault and tracing the route of the cable when used with acoustic DIGIPOINT surge generator generates D.C. high voltage for pressure testing of the underground cables to find out faulty phase and the breakdown voltage with leakage current.

  • Limited Burning Capability (DC High Voltage Testing)

    Limited Burning Capability is integral part of Surge Generator. It's allows to burn down the insulation of cable by Limited Burning Capability. The Limited Burning Capability enables to change a high resistance fault to a low resistance fault in underground Power cables. Thus allowing Reflectometer to be used for low resistance fault pre-location.

    Thumper for Pinpointing of Fault:

    The surges produced help in pinpointing the fault and tracing the route of the cable when used with acoustic fault locator. Surge generator generates D.C. high voltage for pressure testing of the underground cables to find out faulty phase and the breakdown voltage with leakage current. 500 JOULES Energy on 4, 8, 16 KV Range.

TECHNICAL SPECIFICATIONS

Physical
Dimension
45 X 50 X 65 cm3
Weight
90 kg approx.
General
Supply Voltage
220-230/240 VAC, 45Hz up to 60 Hz.
Output
Voltage Range
Short Circuit Current
I
0- 4 KV.
180 mA.
II
0- 8 KV.
80 mA.
III
0- 16 KV.
35 mA.
Maximum Surge Energy
500 JOULES on each range.
Surge Sequence
Manual / Auto (3 to 15 Sec).
Operation Condition
Operating Temperature
-10°C to 50°C.
Storage Temperature
-10°C to 60°C.
Protection
Standard Accessories
Zero Start Interlock.
High Voltage output cable -25 mts.
Range Interlock.
L.T. cable - 15 mts.
Automatic Discharge.
Earthing cable- 15 mts
Over Load Protection.
Discharge Rod.
Thermal breakdown Protection.
Discharge Rod lead- 5mts.
Over current Protection.

Note: Dimension and Weight are subject to change without compromising on the safety and electrical specifications.



SURGE GENERATOR SET

PRE-LOCATION SET

PINPOINTING SET

CABLE IDENTIFICATION SET

CIS

CABLE ROUTE TRACER

DC HIGH VOLTAGE SET